3. Push the ON button of the fan unit (A).
4. Make sure that the fan unit starts.
5. Push the OFF button of the fan unit (B).
6. Make sure that the fan unit stops.
ON/OFF buttons of the blast motor
The ON/OFF buttons of the blast motor are used to start
and stop the blast motor. Refer to
ON/OFF buttons of the blast motor on page 10 .
To do a check of the ON/OFF buttons of the blast motor
1. Turn the emergency stop button clockwise to make
sure that the emergency stop button is disengaged.
2. Set the ON/OFF switch to the ON position.
3. Push the ON button of the blast motor (A).
4. Make sure that the blast motor starts.
5. Push the OFF button of the blast motor (B).
6. Make sure that the blast motor stops.
10
A
B
To do a check of the
A
B
Ammeter
The ammeter shows the blast load onto the surface. The
maximum amperage is shown above the ammeter.
To do a check of the ammeter
Control panel on page 3 for information about
Refer to
where the ammeter is on your product.
1. Start the product. Refer to
page 15 .
2. Wait until the ammeter is in idle position.
3. Stop the product. Refer to
page 18 .
Emergency stop button
The emergency stop button is used to quickly stop the
motors.
To do a check of the emergency stop button
Control panel on page 3 for information about
Refer to
where the emergency stop button is on your product.
1. Turn the emergency stop button clockwise to make
sure that the emergency stop button is disengaged.
2. Start the product. Refer to
page 15 .
3. Push the emergency stop button.
4. Make sure that the motors stop.
5. Turn the emergency stop button clockwise to
disengage.
Operator Presence Control (OPC)
When the OPC is engaged, the motor stops. Refer to
do a check of the Operator Presence Control (OPC) on
page 10 .
To do a check of the Operator Presence Control (OPC)
1. Start the product. Refer to
page 15 .
2. Pull out the OPC key. If the motor does not stop in
3 seconds, speak to an approved Husqvarna service
agent.
Safety instructions for maintenance
WARNING:
instructions that follow before you use the
product.
•
Only do the maintenance as given in this operator's
manual. Let an approved service agent do all other
servicing.
•
If the maintenance is not done correctly and
regularly, the risk of injury and damage to the
product increases.
To start the product on
To stop the product on
To start the product on
To start the product on
Read the warning
2111 - 001 - 21.07.2023
To