Connect the radiator
Switch off the mains supply be-
fore making the electrical con-
nection.
A means of discon-
nection
power supply net-
work with a contact
opening distance of
≥ 3 mm for all poles must be
provided in the fixed ducting
in accordance with the instal-
lation rules.
Heating appliance
Caution:
It is not necessary to disman-
tle the appliance to make the
connections (use the cable
already connected to the ap-
pliance).
When installing the
appliance,
sure that the power
supply
nected.
Rev 0_04 05 23
from
the
BROWN phase
Neutral BLUE OR GREY
make
is
discon-
Fabriqué en Chine
The appliance must
be supplied via a
residual current ap-
pliance (RCD) with
a rated operating differential
current not exceeding 30 mA.
Installation must be carried out
by a qualified electrician.
Connection box
- The electrical connection is
made using a flexible cable
(2X1.0 mm² from the H05 VV- F
series).
- Connect the appliance to the
mains using a junction box with
minimum IP24 protection: brown
wire (phase), blue or grey wire
(Neutral).