Technical data
NOTICE!
Tightening torques
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity of
the thread. The tightening torques are also given on an adhesive label that is
affixed to the pump head.
Pump head size
Tightening torque of the suction/pressure valves:
Tightening torque of the metering head screws:
Materials
Housing: PPO (Noryl)
n
Metering head: PP, optionally PVDF
n
Diaphragm: PTFE - EPDM composite diaphragm
n
Seals: FKM or EPDM, optionally PTFE or FFPM (Kalrez)
n
Valve balls: Ceramic, optionally PTFE or stainless steel 1.4401
n
Valve springs: Hastelloy C-4
n
Colour: Blue, RAL 5007
n
Special versions are available on request.
Packaging
Data
Packaging size (L x W x H)
Weight (depending on pump design)
Due to the low weight, no special lifting gear is required during transport.
MAN046879 Rev. 12-12.2023
5 l/h and 11 l/h
2 ± 0.2 Nm
3,75 ± 0.25 Nm
395 x 290 x 360 mm
82
30 l/h and 50 l/h 120 l/h
2,8 ± 0.2 Nm
4 ± 0.2 Nm
6 ± 0.25 Nm
6 ± 0.25 Nm
Value Unit
3,5 - 6 kg