en-us_main.book.book Page 12 Friday, July 14, 2023 11:13 AM
12 INSTALLATION
-
A
B
C
D
E
F
G
Optional Accessories
• SKSUK240DS - Stainless Steel Panel and
Handle Kit for 24-inch Undercounter Drawer
Refrigerator
- This unit can be installed with an optional
Stainless Steel Panel Kit. Kit includes two
drawer panels and two handles.
• SKSUK240WS - Stainless Steel Panel and
Handle Kit for 24-inch Undercounter Wine
Refrigerator
- This unit can be installed with an optional
Stainless Steel Panel Kit. Kit includes door
panel and handle.
• SKSHK230HS - Handles for use with custom
panel
- 22 3/4" (578 mm) medium brushed aluminum
handle
Moving Appliance into
Enclosure
Installing the Anti-tip Brackets
WARNING
• To avoid injury or damage, check for electrical
wires or plumbing in walls before drilling or
installing screws.
• The anti-tip bracket should be firmly fixed to a
concrete wall/wood with strength of 15 t or
greater, or a wall with equivalent strength. (The
structure where the bracket is fixed should be a
solid structure that can withstand a force of 70
kgf or greater.)
Install the anti-tip brackets at the rear of the
Dimensions
enclosure, locating the brackets based on stud
locations and product and enclosure dimensions.
3 3/4'' (94.5 mm)
2 7/16'' (62.4 mm)
1 7/16'' (37 mm)
15/16'' (24.4 mm)
Φ 3/16'' (4.8 mm)
7'' (178 mm)
1 1/4'' (57.9 mm)
NOTE
• Brackets must be attached as shown below. The
C
Anti-Tip Bracket x 2
-
Dimensions
33 3/16" (843 mm) min.
A
33 9/16" (853 mm) max.
B
2 3/8" (60 mm)
C
3 3/4" (90 mm)
brackets could fail to prevent tipover of the unit
if installed in an alternate orientation.
A
B