Installation
Instructions
PREPARATION
TOOLS AND MATERIALS
YOU WILL NEED
• Saw
• Flat-blade
screwdriver
• Electrician's
pliers
• Duct tape
• Measuring tape or scale
• Carpenter's
square
• 7/16" wrench or socket set
• Drill and drill bit
• Sheet metal screws
• Junction
box*
• 3/4"flexible
conduit*
• Electrical wire per local code*
• Wire nuts*
• Ductwork
• NOTE: Electrical installation
kit JXCK89 mag be
ordered separatelg
and includes all the parts
necessarg to connect the cooktop to tgpical
rough-in wiring.
CAUTION:
FOR PERSONAL
SAFETY,
REMOVE
HOUSE FUSE OR CIRCUIT BREAKER
BEFORE BEGINNING INSTALLATION.
ELECTRICAL
REQUIREMENTS
This appliance must be supplied with the proper voltage
and frequency, as listed in these Installation Instructions,
and connected to an individual, properly grounded branch
circuit, protected by a 40-amp circuit breaker or time
delay fuses.
All wire connections must be made in accordance with
local codes and properly insulated. Checkwith your local
utility for governing electrical codes and ordinances. In the
absence of local electrical codes,the National Electrical
Code,ANSI/NFPANo. 70 - Latest Edition,governing electric
range installations,must be followed.
A copy of the National ElectricalCodecan be obtained by
writing to:
National FireProtection Association
Batterymarch Park
Quincy, HA 02260
EffectiveJanuary 1, 1996,the National ElectricalCode
requires that new, but not existing, construction utilize a
four-conductor connection to an electric range. When
installing an electric range in new construction, follow the
instructions in NEW CONSTRUCTION AND FOUR-
CONDUCTOR BRANCH CIRCUIT CONNECTION.
You must use a three-wire, single-phase AC 208Y/120Volt
or 240/120 Volt, 60 Hertz electrical system with separate
ground. If you connect to aluminum wiring, properly
installed connectors approved for use with aluminum
wiring must be used.
30" COOKTOP (DIMENSIONS
FOR REFERENCE ONLY)
Unit shown fullg assembled.
227Ad '
_(22gAd ' SS)_,-
.,_
283A,,
Unit must be vented to the outside!
15