Installation
Instructions
ELECTRICALCONNECTIONS
ETI BEFORE MAKING ELECTRICAL
CONNECTIONS
Note to Electrician: The power leads supplied with this
appliance are UL-recognized for connection to large
gauge household wiring.
The insulation of these leads is rated at temperatures
much higher than the temperature
rating of household
wiring. The current carrying capacity of a conductor is
governed by the wire gauge and also the temperature
rating of the insulation around the wire.
Aluminum Wiring - _,WAR
NING:
IMPROPER CONNECTION OF ALUMINUM HOUSE
WIRING TO THE COPPER LEADS CAN RESULTIN
SERIOUS PROBLEMS.
Attach copper wires to aluminum wiring using special
connectors designed and UL-listed for joining copper
to aluminum. Follow the connector manufacturer's
recommended
procedure closely.
Service Loop - Leave a loop in the wires to the
cooktop so that the cooktop can be lifted 12 inches
without having to disconnect the wiring.
ELECTRICAL REQUIREMENTS*
Model #
Voltege
Frequency
KW
PP989
120/240V
60Hz
9.1KW
120/208V
60Hz
6.9KW
*For reference only. Verify with product rating plate.
•
Plate
Electrical installation
kit J×CK89 may be ordered
separately
and includes all the parts necessary
to
connect the cooktop to typical
rough-in wiring.
INSTALL 3/4" FLEXIBLE CONDUIT
Remove the screws holding
the wire compartment
cover
and remove the cover.
Feed the power
supply leads
through the
conduit; be sure to
leave enough length
to properly connect
these leads to the
cooktop power leads.
Thread the leads
through an anti-
short bushing and
firmly seat the
bushing in the end
of the conduit.
Feed the leads
through the hole
in the wire
compartment.
As local codes
permit purchase
a listed conduit
connector suitable
for the size conduit.
Insert the conduit
through the
connector and
attach it to the
cover. Allow
enough slack to
easily attach the
wires to the
cooktop.
Note: Do not install
the cooktop without
a listed conduit
connector. The
conduit connector
should be installed
before reinstalling
the wiring cover.
When complete,
reinstall the wire
compartment
cover.
Power Supply
Anti-Short
Leads
Bushing
Conduit
Bushing(FullySeated)
Conduit
Connector
Conduit
25