2.1. Normal Machine Operation

Start Here for Safety

2.1.1.
This document is designed to remind the person operating this washer-extractor what is required
to operate this machine. Do not attempt to operate this machine before a trained operator has
explained the details to you.
DANGER 1 : Multiple Hazards—Careless operator actions can kill or injure personnel,
damage or destroy the machine, damage property, and/or void the warranty.
CAUTION 2 : Electrocution and Electrical Burn Hazards—Contact with electric power
can kill or seriously injure you. Electric power is present inside the cabinetry unless the main
machine power disconnect is off.
• Do not unlock or open electric box doors.
• Know the location of the main machine disconnect and use it in an emergency to remove
all electric power from the machine.
• Do not service the machine unless qualified and authorized. You must clearly understand
the hazards and how to avoid them.

Check Switch Settings

2.1.2.
Display or Action
Supplement 1
®
Some Milnor
washer extractors do not use a speed sensing device to verify that the basket has
stopped rotating. Therefore, when power is first applied to the machine, at least 80 seconds
must elapse before any further operations can be attempted. This provides sufficient time for
the basket to coast to a complete stop if power was lost while the machine was in a high speed
extract and restored before the basket stopped.
PELLERIN MILNOR CORPORATION
Explanation
Check that the run/program keyswitch is at
B
Check that any emergency stop switches are in the out position.
:
Check that the master switch, if provided, is at
m/M
The Power-up Safety Delay
8
.
B
.
M