Skilled technicians only appointed by the same manufacturer or
by authorized dealers, are allowed to install the car lift. Serious
damage to people and equipment can be caused if this rule is not
followed.
INSTALLATION REQUIREMENTS
The car lift must be installed according to the specified safety
distances from walls must be 1000 mm at least, taking into
consideration the necessary space to work easily. Further space for
the control site and for possible runways in case of emergency is also
necessary, the room must be previously arranged for the power supply
and pneumatic feed of the car lift. The room must be 4000 mm in
height, at least, the car lift can be placed on any floor, as long as it is
perfectly level and sufficiently resistant.
-All parts of the machine must be uniformly lit with sufficient light
to make sure that the adjustment and maintenance operations
specified in the manual can be performed safely, and without areas of
shadow, reflected light, glare and avoiding all situations that could give
rise to eye fatigue.
-The lighting must be installed in accordance with the laws in
force in the place of installation.
- The thickness and leveling of the base concrete are essential
- Thickness of concrete ≥ 250mm, the leveling of whole length ≤
5mm.
LINE CONNECTION
Connect the electrical and oil line according to the electric wiring
diagram and oil line connection
To avoid the unexpected lift closure due to mechanical safety
device release insert wooden pieces in the inner part of the base
frame.
Pay attention not to work under the lift until the hydraulic
system has not been completely filled with hydraulic oil.
To insert the lift into the recess, sling the lift as described
and pay attention not to damage the hoses and electrical cables.
Before placing the pneumatic and hydraulic hoses to the
control unit, stick adhesive tape on the pipe fittings in order to
protect the hoses from dust and impurities which could damage
the hydraulic system.
Perform electric, hydraulic and pneumatic connections, follow
carefully the relevant numbering. Regarding the proper connections
necessary to make the car lift perfectly working.
Skilled personnel only is allowed to perform the operations
shown below.
-open the control box front cover
-connection of power supply: the connection wires (5x1.5mm
power supply are connected to terminals R-S-T-N The ground wire is
connected under the bolt marked ground.
-the electric panel are arranged by the manufacturer for operating
at 400V three-phase, therefore if you wish the lift to operated at 230V
three-phase, change the connection on the motor.
R
004152 – 04/2021
S
T
N
PE
Connect the electrical cables ensuring that they coincide with the
numbers on the control console junction box.
HYDRAULIC HOSES CONNECTION
Connect the hydraulic hoses as oil route connection
drawing (Pag. 23).
ELECTRICAL CARRIAGE OIL LINE CONNECTION:
The oil line of electrical carriage from manual selector to oil tank.
ADD OIL AND CHECK THE ORDER OF PHASE.
- Open the hydraulic oil tank, add 20L of hydraulic oil into the oil
tank, the hydraulic oil is provided by the user.
Make sure the clean of hydraulic oil, prevent any impurity into the
oil line, lead the digest of the oil line and no working of the
solenoid valve.
-Check carefully to ensure that electrical connections have been
made properly. This can be done by activating the lifting button
momentarily. If the lift goes up, connections have been made properly.
If it does not go up, the two phases in the mains supply connection
should be interchanged. The main switch should be disconnected
previously.
MAIN MACHINE OIL BLEEDING ADJUSTMENT
ATENTION: This operation should only be done
without load
1- Unscrew one complete turn the maximum pressure screw valve,
which is in the hydraulic unit.
2
) for
2- Turn the selector switch on the control panel to the "Main Lift"
position.
3- Raise the lift to the maximum height by pressing the "
push-button and RED button.
4- When the platforms reaches the position of the upper mechanical
position, continue pressing at intervals 3-4sg and stop 2sg. Repeat
that 5-6 times.
5- Press "
" to lower the lift to its lower position and carry out a
service of raising and lowering without load in order to observe that the
"
Pág. 18