3 Transport/Storage/Disposal
3 Transport/Storage/Disposal
3.1 Checking the condition upon delivery
1. On transfer of goods, check each packaging unit for damage.
2. In the event of in-transit damage, assess the exact damage, document it and
notify SFA or the supplying dealer and the insurer about the damage in writing
immediately.
3.2 Transport
DANGER
Improper transport
Danger to life from falling parts!
Damage to the pump set!
▷ Attach lifting accessories to the pump set handle only.
▷ Never suspend the pump set by its power cable.
▷ Use the lifting chain/rope included in the scope of supply exclusively for
lowering or lifting the pump set into/out of the pump sump.
▷ Securely attach the lifting chain/rope to the pump and crane.
▷ Use tested, marked and approved lifting accessories only.
▷ Observe the regional transport regulations.
▷ Observe the product literature supplied by the lifting accessory manufacturer.
▷ The load-carrying capacity of the lifting accessory must be higher than the
weight indicated on the name plate of the pump set to be lifted. Take into
account any additional system components to be lifted.
3.3 Storage/preservation
If commissioning is to take place some time after delivery, we recommend that the
following measures be taken:
CAUTION
Improper storage
Damage to the electric cables!
▷ Support the electric cables at the cable gland to prevent permanent
deformation.
▷ Only remove the protective caps from the electric cables at the time of
installation.
CAUTION
Damage during storage due to humidity, dirt or vermin
Corrosion/contamination of pump (set)!
▷ For outdoor storage cover the pump (set) and accessories with waterproof
material and protect against condensation.
CAUTION
Wet, contaminated or damaged openings and connections
Leakage or damage to the pump!
▷ Clean and cover pump openings and connections as required prior to putting
the pump into storage.
Sanipump VX 65/80-EN
73 of 449