Descargar Imprimir esta página

SFA Sanipump VX 65 Serie Manual De Funcionamiento página 83

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 258
Resonances Any resonances at the usual excitation frequencies (1 x and 2 x rotational frequency,
Resonances Any resonances at the usual excitation frequencies (1 x and 2 x rotational frequency,
82 of 449
5 Installation at Site
5.2 Checks to be carried out prior to installation
5.2.1 Preparing the place of installation
Place of installation for stationary models
WARNING
Installation on mounting surfaces which are unsecured and cannot support the
load
Personal injury and damage to property!
▷ Use a concrete of compressive strength class C25/30 which meets the
requirements of exposure class XC1 to EN 206-1.
▷ The mounting surface must have set and must be completely horizontal and
even.
▷ Observe the weights indicated.
vane passing frequency) must be prevented both in the foundation and in the
connected piping, as such frequencies may cause extreme vibrations.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
Place of installation for transportable models
WARNING
Incorrect positioning / incorrect placing down
Personal injury and damage to property!
▷ Position the pump set vertically with the motor on top.
▷ Use appropriate means to secure the pump set against tilting and tipping over.
▷ Refer to the weights given in the data sheet/on the name plate.
▷ Adjust the handle position.
vane passing frequency) must be prevented both in the foundation and in the
connected piping, as such frequencies may cause extreme vibrations.
1. Check the structural requirements.
All structural work required must have been prepared in accordance with the
dimensions stated in the outline drawing/general arrangement drawing.
5.2.2 Checking the lubricant level
The lubricant reservoirs have been filled with an environmentally-friendly, non-toxic
lubricant at the factory.
1. Position the pump set as shown.
Sanipump VX 65/80

Publicidad

loading