- perform a third wheel spin.
If the calibration program has been completed successfully, this will be confirmed
by a message of approval. If not the "Err 3" message will be displayed. In this case
the calibration should be repeated correctly, checking that the weight used actually
corresponds to 100 g ("3.5" oz.).
The self-calibration program ends with the display showing the imbalance values
for the wheel (ignoring the sample weight).
NOTES
- Remember to remove the 100 g (3.5 oz.) weight at the end of the procedure.
- The
the program.
THE CALIBRATION DESCRIBED ABOVE IS VALID FOR ANY TYPE OF CAR
WHEEL!
This must be carried out when the machine requests it by displaying the message
Err 4, or when a difference is noticed between the distance values measured and
those read on the millimetre rule on the sensor rod.
After displaying the list of utility programs:
- select the
- select the
- bring the sensor to the rest position;
- select the
the sensor;
- extract the sensor arm to a distance of 200 mm. To read the distance, use the rule
on the sensor rod;
-select the
sensor;
- extract the sensor arm to a distance of 400 mm. To read the distance, use the rule
on the sensor rod;
- select the
the sensor.
If the calibration has been carried out successfully, a message of consent is
temporarily displayed. On the other hand, display of the message "Err 20"
indicates that the position of the sensor during the calibration was not correct.
Position it correctly, as described previously, and repeat the procedure.
90
Exit icon can be selected at any moment to break off execution of
Sensor calibration
Recall other icons icon;
Sensor calibration icon;
Confirm sensor calibration icon to confirm the position of
Confirm sensor calibration icon to confirm the position of the
Confirm sensor calibration icon to confirm the position of
ET 88 operator's manual