SURFACE INSTALLATION AND ELECTRICAL WIRING (OPTIONAL)
Note: A Surface Mount Kit (refer to the cabinet's instructions, sold separately) is required for the following instructions.
1. Prepare the electrical rough-in as shown below.
2. Remove the two #6-32 screws holding the electrical enclosure cover in place. Set the cover and screws aside in a safe place.
3. With the electrical cover removed, feed the field wire through the field wire strain relief at the back of the electrical enclosure and
secure.
4. Make necessary Cat5 cable connections at the back of the enclosure according to the electrical diagram on page 10. To avoid
any potential electrical interferences, the provided ferrite should be installed. After connections have been made, push the ferrite into
rough-in hole.
5. Mount the cabinet in place following the steps provided in the cabinet's or Surface Mount Kits instructions.
6. Make the electrical connection according to the electrical diagram on page 9.
Note: Leaving too much field wire in the enclosure could prevent it from closing properly and may cause damage to the internal
components.
7. Replace the electrical cover utilizing the two #6-32 screws removed in Step 2.
Cabinet Width + 1/2"
1
3
2
Ø 1-1/4" (32mm)
12" (305 mm)
1-1/4" (32mm)
30" Tall Cabinet = 12-11/16" (322mm)
36" Tall Cabinet = 18-11/16" (475 mm)
40" Tall Cabinet = 22-1/16" (560 mm)
Wiring access
C L
© 2022 Robern, Inc. 701 N. Wilson Ave. Bristol, PA 19007 U.S.A.
Part no. 209-1426 || 09-MAY-2023