3.2.4.3.1- Hydraulic installation
Attach the probe holder to the wall by means the screws and wall plugs
included in the box.
Ensure that the probe is correctly leveled.
As shown in the following Picture, the water inlet is in the lower left part of the
probe holder, while the water outlet is in the upper right side of the probe
holder.
In case a pH probe must be installed, it can be placed in the central part of the
probe holder, removing the yellow cap and install the pH probe.
Additional recommendations:
- If possible, install a hose valve at input, and another one at output to ease the
cleaning and maintenance tasks.
-The probe holder water inlet can be connected after the filter, but then a good
maintenance of the filter cleaning must be ensured, otherwise the measure can
be affected by the chlorine consumption inside the filter.
-As an alternative, the inlet can be connecter before the filter, but then it is
strictly necessary to install a specific cartridge filter to avoid the probe
contamination.