filtreau BSONE-EVO-10 Manual De Usuario página 87

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

4.1.6.7- Acid - Alkaline
Access the configuration menu of the equipment to pass the pH control from
acid to alkaline. To do this, press "OK" in the main screen, in configuration "S"
press button  until reaching the ACID line. Press "OK" and the letter "N" will
appear with the arrow . Select "S" to remain in the ALKALI screen.
4.1.6.8- Automatic shutdown and error message.
If the acid pump shuts down and the message "pH ERROR" appears, the pump
has been operating too long without the pH value lowering to the required
level. The causes could be:
-There is no acid.
-Problem in the pump or in the acid duct.
-The probe or probe cable are damaged.
NOTE: to cancel the error alarm, press the "OK" button
4.1.7- Relay
The BSONE-EVO series equipment has a programmable auxiliary relay that can
be used to control the filtering pump, swimming pool lighting and others
features See pages 23 and 24 of this manual for further details.
4.1.7.1- Start/Stop
This manually turns the relay on / off.
4.1.7.2- Program (1/24h)
This allows one single programming a day from 0h to 23.59.
87 / 95
Manual BSONE-EVO v.2

Publicidad

Capítulos

Tabla de contenido
loading

Productos relacionados para filtreau BSONE-EVO-10

Este manual también es adecuado para:

Bsone-evo-20Bsone-evo-35

Tabla de contenido