EN
3.6 POWER SUPPLY
DANGER
Electrical connection work performed by an
unqualified individual.
Risk of death by electric shock!
ÖThe electrical connection must be performed by
a qualified and licensed electrician.
ÖThe electrical installation must meet the current
standards in the country (UK : BS 7671).
The electrical supply must be used exclusively to power the
appliance and must be connected to a differential circuit breaker
set to 30 mA, protected by a 5 A fuse.
4. FITTING THE WALL CLADDING
4.1 REMOTE BUTTON
option for Sanicompact® Comfort+ Applique,
Sanicompact® Comfort Box, Sanicompact® Comfort Style
When installing a box panel, it is possible to move the control
button to the top of the box panel.
9.1
• Figure
. Spread out the two lugs on each side.
9.2
• Figure
. Remove the capsule.
9.3
• Figure
. Unscrew the nut.
• Remove the entire button and proceed in reverse order to place
it in the hole designed for this purpose on your box panel.
• Seal the hole in the bowl with the supplied cover.
Continue with the preparation of the wall cladding:
– Sanicompact® Comfort+ Applique, Sanicompact® Comfort Box,
Sanicompact® Comfort Style : box panel cladding go to
paragraph 4.2.
– Sanicompact® Comfort+ : not provided board cladding (like
plasterboard) go directly to paragraph 4.5.
4.2 PREPARATION OF THE BOX PANEL
(Sanicompact® Comfort+ Applique, Sanicompact®
Comfort Box, Sanicompact® Comfort Style)
10
• Figure
. Prepare a cut-out to allow the water injection
passage according to the previously selected seat height:
– for a half-height adjustment, the cut-out is 40 mm;
– for an adjustment in the upper position, the cut-out is 70 mm;
– for a low adjustment, no cut-out is necessary.
• Continue with the fitting of the box panel cladding:
– Sanicompact® Comfort+ Applique, Sanicompact® Comfort Box
go to paragraph 4.3.
– Sanicompact® Comfort Style go directly to paragraph 4.4.
4.3 FITTING THE BOX PANEL FOR Sanicompact®
Comfort+ Applique AND Sanicompact® Comfort Box
11.1
• Figure
. Mark out the location of the evcuation passage on
the box panel
• Cut the box panel to create the evacuation passage.
11.2
• Figure
. Glue two strips
shown above.
11.3
• Figure
. Glue the two remaining strips on each side to the
inside of the box panel as shown.
11.4
• Figure
. Insert the box panel up to the wall, apply pressure
to the hanging strips so that they stick together.
11.5
• Figure
. Remove the protective film and complete the
installation with a silicone seal around the casing if necessary.
• Finalize the complete installation: go directly to paragraph 5.
4.4 FITTING THE BOX PANEL FOR Sanicompact®
Comfort+ Style
12.1
• Figure
. Mark out the location of the evcuation passage on
the box panel
• Using a hole saw or a jigsaw fitted with a steel blade, cut the box
panel to create the evacuation passage.
12.2
• Figure
. Insert the box panel right up to the wall using the
inside of the box brackets to centre the box horizontally.
12.3
• Figure
. Remove the protective film and complete the
installation with a silicone seal around the casing if necessary.
• Finalize the complete installation: go directly to paragraph 5.
4.5 PREPARATION AND ASSEMBLY OF BOARD
CLADDING FOR Sanicompact® Comfort+ (Figure
• Place the plasterboard facing the frame previously fixed to the
wall.
E
on each side of the frame as
13.1
• Figure
. Locate and drill the position of the bowl support
rods on the plasterboard.
• Place the foam gasket
2 holes on the bowl support rods.
13.2
• Figure
. Trace the inner contour of the foam gasket on the
cladding wall.
13.3
• Figure
. Remove the foam gasket and cut the plasterboard
according to the outline.
13.4
• Figure
. Finish the complete installation (possibly tiling) of
your cladding wall.
Note: If you are tiling your cladding wall, you must cut the tiles in
the same way as the plasterboard.
5. CONNECTING AND INSTALLING THE TOILET
BOWL
IMPORTANT
Before carrying out the connections, check that the threaded
A
rods
are correctly screwed into the frame and that the inserts
B
are positioned as shown in figure
outwards).
• Reposition the foam gasket that will serve as a support between
the bowl and the wall.
• Present the bowl supported on its axles.
5.1 CONNECTING THE DISCHARGE PIPE
Note: Use the polystyrene shim included in your packaging to
support the ceramic bowl during this operation.
K
• Insert the hose
into the discharge pipe.
• Secure the hose by using the clamp
Option: Connection of a handbasin (figure
• Connect the hand basin outlet Ø40 mm to the hose
• Secure the connection with a clamp
5.2 CONNECTING TO THE WATER SUPPLY
14
Figure
. Connect the end of the water supply hose to the
previously made connection.
5.3 FITTING THE TOILET BOWL
15.1
• Figure
. Adjust the distance between the inserts using the
measurement Y from section 3.2.
• Tighten the double nuts according to the measurement
• Once the connections have been made, adjust the inserts
that the end of the insert is positioned 75 mm from your cladding.
• The hollows must point outwards.
15.2
• Figure
. Replace the foam gasket
the bowl support rods.
• Position a grub screw
• Tighten the grub screws with the supplied wrench
bowl is completely immobile.
• Close with the hole covers
6. FUNCTIONAL TEST AND COMMISSIONING
• Plug in the device.
• Fully open the water inlet in order to rinse properly.
• Start the normal cycle by pressing the dark grey part.
• Throw a few pieces of toilet paper in the bowl and repeat the
flush cycle.
• Check that the connections do not leak.
• Carry out several functional tests.
Handbasin option:
• Let the tap of the handbasin run, the device should start
automatically.
• Check that the connections do not leak.
7. USE AND PRECAUTIONS
7.1 PRECAUTIONS FOR USE
DANGER
ÖNever use the device in the event of a power
failure!
NOTICE
13
)
ÖDo not use the device to dispose foreign bodies
such as periodical swabs, condoms, rags, cotton,
solvents, oil, etc. that could damage the device.
ÖSuch use will invalidate the warranty.
16
F
on the cladding wall by positioning the
15.1
(with the hollow facing
I
supplied.
6.3
)
J
(see figure 7.2).
F
and place the bowl on
G
in the hole on each side.
M
.
L
.
Y
.
B
so
H
until the