Trigger mode
options 14.
Option 1
Option 2
Option 3
Option 4
Option 5 (factory setting)
Option 6
Option 7
Option 8
9. Functions – Settings by potentiometer
COM 1 + COM 2
Potentiometer 5.
Twilight setting
The chosen response threshold
can be infinitely varied from ap-
prox. 10 – 1,000 lux.
Examples of use
Night-time mode
Corridors, foyers
Stairs, escalators, moving walkways
Washrooms, toilets, switchrooms, canteens
Sales floor, kindergartens, nursery school rooms,
sports halls
Work rooms: offices, conference and meeting
rooms, precision assembly activities, kitchens
Working areas requiring good light:
Laboratory, technical drawing, precision work
Daylight mode
Note: Depending on the site of installation, the setting may need to be corrected by 1 – 2 marks on the
scale.
The light level is measured at the sensor.
Potentiometer 6.
Time setting
Stay-ON time for switching
output 1
Setting 30 sec. – 30 min.
Initial presence
Both
Both
PIR
US
Either
US
PIR
Either
Control dial turned fully clockwise:
MAX daylight mode
Control dial turned fully an-
ti-clockwise: MIN night mode
The chosen stay-ON time is in-
finitely variable from a minimum
of approx. 30 sec. to a maxi-
mum of 30 min. Intrinsic light
- 26 -
Maintain
presence:
Either
Both
Either
Either
Either
US
PIR
Both
Depending on the site of instal-
lation, the setting may need to
be corrected by 1-2 marks on
the scale.
Light-level settings
is calibrated after 3 min. When
the threshold is exceeded, the
sensor switches OFF after the
stay-ON time expires.
DIP
DIP
6
7
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
min
1
2
3
4
5
>=6
max
DIP
8
OFF
ON
OFF
ON
OFF
ON
OFF
ON