INFORMATION ABOUT GAS-FED TILTING BRATPAN DOMINA SERIES
This manual applies to our Gas-Fed tilting Bratpan Domina Series, Type A Category II (Natural Gas and L.P.G.).
See table 1.1 - 2.6
The label according to EN437 and EN203 regulations, Part 1, is located at back and inside.
Example for Italy label:
Category II 2H3÷
Pe = Incoming Pressure
Pi = Nozzle Pressure
2.2
LAWS, REGULATIONS AND TECHNICAL DIRECTIVES TO BE COMPLIED WITH
The following indications should be observed during installation:
- Accident and fire regulations in force
- Prescriptions by the Gas Supply Company, which should issue an authorisation before installation.
- Instructions for the "Installation of gas equipment"
- Hygienic regulations.
2.3
INSTALLATION PLACE
- The unit should be installed in adequately ventilated places. (This unit requires a draft of at least 2 cu.m/hr x kW P.T.
(Thermal capacity).
- Install the equipment in compliance with the safety rules applicable in the country where the equipment is installed
2.4
POSITIONING
- The various units may be installed individually or together with other units of our range.
- This unit is not suitable for encasing.
- The distance between side walls must be a minimum of 10cm; should the distance be less or the wall or floor material be
flammable, it is essential to use a thermal insulator.
2.5
WATER CONNECTIONS
In order to perform a correct installation, it is essential that :
- The unit be supplied with drinkable water.
- The water inlet pipe be connected to water main by check-valves to be shut off when the unit is not operating or when
servicing it.
- Between check-valves and the pipe connecting the folding, mechanical filter be installed in order to prevent any ferrous
slag to be introduced, which may corrode by oxidation and in the long run oxidise the folding itself. It is advisable,
however, before connecting the last piping section the folding fittings, to drain a certain amount of water in order to clear
the pipes from any ferrous slag.
V
IT-GR-GB-ES-IE
PT
Cat.
II2H3+
II2H3+
P n
20,29/37
20,29/37
LU
IS-DK-FI-SE
Cat.
II2E3P
II2H3B/P
P n
20,37,50
20,29
G20
Qn
kW
(Hi)
G25
- 17 -
Mod.
Matr.N°
Hz
kW
FR-BE
NL
II2E+3+
II2L3P
20/25,29/37
25,30,50
AT-CH
DE
II2H3B/P
II2ELL3B/P
20,50
20,20,50
m
3
/h
G30
m
3
/h
G31
Type
tipo
mbar
mbar
NO
I3P
30
Kg/h
Kg/h
GB