OPERATING FAULTS - CAUSES- SOLUTIONS
Wear protective clothing with electrostatic
properties.
DANGER
Powered electric panel. Risk of electrocution.
IMPORTANT
Synoptic panel connected to the cover. Do not pull.
In case of lock-out, hold down the lockout reset button (8).
If the lock-out occurs again, proceed as follows:
•
Disconnect the power supply using the system main switch.
•
Remove the panel cover as described in chapter "Electrical
Connections".
•
Activate the power supply using the system main switch.
•
Check the number of flashes on the equipment.
To activate the diagnosis phase (red light blinking fast) press the button for more than 3 seconds. The table below indicates the meaning of the
block or fault cause according to the number of flashings (always red).
Holding the reset button down for at least 3 seconds, the diagnostics function will be interrupted.
The diagram below shows the operations to be carried out to activate the diagnostic functions even with communication interface through the
"OCI400" connection cable.
Operating position
O n
•
During the fault-finding time, the device is disabled.
0006160660_202402
Operating position
Visual indication
E K
Colour code table
> 3 s
x x x x xx x x
x x x x xx x x
x x x x xx x x
x x x x xx x x
x x x x xx x x
x x x x xx x x
Operating position
PC / analyser interface
diagnostics
E K
> 3 s
ENGLISH
8
R e se t
E K
< 3 s