ANOMALIES - CAUSES - REMEDIES
The table shows possible faults that may cause the grinder-doser not to work and/or not
to function properly. For each anomaly, the possible cause is indicated along with the
actions to be taken to restore the correct operation of the appliance.
Anomaly
Cause
The grinder-doser
No power supply.
does not switch
on.
The coffee beans
Locking slide closed.
do not fall out
of the supply
hopper.
The system
The backup battery
loses data
of the machine
from previous
management system
settings when it is
is fl at.
switched on.
First daily doses
The
icon
A change in the
(Yellow scales)
type of coffee in
appears on
the hopper
the display to
Coffee with a high
indicate that the
percentage of
weight of the last
robusta
dose dispensed
was not within
Grinding blades
tolerance of the
not well-tuned yet
set weight.
Fiorenzato |
Series_00 Ed. 04/2022
EN
Remedy
Make sure that the switch is in the
"I" (ON) position;
Make sure that the thermal-
magnetic circuit breaker upstream
of the socket (if present) is in the
"ON" position.
Make sure that the power cable is
intact and correctly connected to
the power plug and the socket on
the appliance.
Open the locking slide.
Contact the service department to
replace the backup battery.
Dispense further doses without
changing any settings on the
appliance.
After two doses in succession
not within tolerance, the XGi
software automatically calculates
the seconds required to
correctly dispense the set dose.
Notifi cation of recalculation is
indicated by the appearance of
the
icon (Blue scales).
The doses dispensed after
recalculation will be correct
and will be indicated by the
appearance of the
icon
(Green scales).
45 / 49
EN
Anomaly
Cause
Possible addition
The
icon
(or removal) of
(Red scales)
weight on the
appears on
appliance during
the display to
the dispensing/
indicate that a
dose weighing
fault has occurred
cycle.
in the weighing
The appliance
of the last dose
is placed on an
dispensed.
unstable work
surface that
affects the correct
detection of
weight.
The appliance is
connected to an
unsuitable power
strip.
46 / 49
Series
Remedy
Make sure that the appliance is
placed on stable, vibration-free
surface.
Check and/or replace any power
strip to which the device is
connected.
Dispense further doses until
the
icon (Green scales)
indicates that the dose dispensed
is correct.
After the third incorrect dose
in succession (
-
three "Red scales" icons appear
on the display), the following
message of control appears full
screen:
Attention!
Carry out a perimeter control of the grinder-doser.
If the problem persists, reset the dose from the menu.
SETTINGS MENU >> RESETTING DOSES
After returning to the HOME
page, the XGi system enables
the sequence for the forced
recalculation of the doses and
it will be necessary to dispense
three doses following the
instructions on the display in
order to allow the XGi system to
perform the recalculation.
Notifi cation of successful
recalculation is indicated by the
appearance of the icon
(Blue scales).
The doses dispensed after
recalculation will be correct
and will be indicated by the
appearance of the
icon
(Green scales).