Series
Anomaly
Cause
After dispensing,
•
A foreign body
the message
is placed on the
"Weight detection
appliance and
error" appears full
the XGi system
screen.
fails to detect the
tare weight.
•
The appliance
Attention!
Weight detection error. Make sure that the grinder-doser
is positioned in a place with little vibration and away
is subjected to
from air currents.
vibrations and/
or strong air
currents.
•
Possible foreign
body between the
curved protective
elements and the
machine body.
The icon
The grinding blades
are close to the
"
"
appears
manufacturer's
on the display
working hour limit
accompanied by
and therefore their
an alert message
replacement must be
about the need
planned.
to replace the
grinding blades.
Fiorenzato |
Series_00 Ed. 04/2022
EN
Remedy
•
Check the perimeter of the
grinder-doser and remove any
objects that may be placed on the
appliance.
•
Make sure that the grinder-
doser is not subject to vibrations
from other appliances (e.g.
dishwashers, blenders, juicers,
etc.) or strong air currents from,
for example, a fan.
•
Check and remove foreign
bodies from the curved protective
elements of the appliance using a
fi ne brush, a suction device or a
folded piece of paper.
•
The grinder-doser can be used
until the set time limit is reached.
When the time limit has been
reached, the grinding blades must
be replaced in order to guarantee
maximum machine effi ciency,
following the instructions given in
paragraph 6.1.5.
•
Once they have been replaced,
the specialist technician resets
the time counter for the grinding
blades.
47 / 49
EN
Anomaly
Cause
During grinding
Triggering of the
the motor stops.
motor thermal-
magnetic circuit
breaker due to
blockage of the
grinding system if
objects or foreign
bodies are between
the grinding blades.
ATTENTION! If the anomaly persists even after carrying out the
recommended corrective actions, or if functional anomalies occur that
are not indicated in the table, contact your local dealer, who will decide
whether to contact the Fiorenzato M.C. S.r.l. service department or have
the appliance repaired or overhauled by a specialised technician.
48 / 49
Series
Remedy
•
Switch off the appliance and
wait until it has cooled down
completely.
•
Disconnect the appliance from
the mains power supply.
•
Close the locking slide and
remove the supply hopper.
•
Clean the grinding chamber and
remove any foreign bodies.
•
Reassemble the appliance and
start a grinding cycle.
Fiorenzato |
Series_00 Ed. 04/2022