Descargar Imprimir esta página

Ingeteam RAPID 60 Manual De Instalacion Y Uso página 61

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

Shutting down the unit
12. Shutting down the unit
This section describes the procedure to shut down the unit. If you wish to work inside the unit, you must carry out
these instructions in the order shown here to remove the power.
1.
If there is an active charge process, finalize the charge session.
2.
Press the emergency stop button if the charger has one.
3.
Remove AC voltage from a means of disconnection outside the unit.
4.
Wait 10 minutes for the internal capacitances to discharge, the hot parts which may cause burns to cool
and the fan blades to stop turning.
5.
Open the unit and, using the appropriate PPE, check the absence of voltage in the AC input.
6.
Signal cut-off point with a sign reading "Caution no switching...". If necessary, rope off the work area.
300000772 - Monterings- och bruksanvisning
Ingeteam
EN
ES
FR
IT
SV
61

Publicidad

loading

Este manual también es adecuado para:

Rapid 60 oneRapid 60 duoRapid 60 trio