MAINTENANCE
Alarm signals, causes and possible remedies
Alarm
ALL 11
INSUFF. DRAUGHT
ALL 12
CLEANER FAULT
Every alarm causes the appliance to switch-off immediately. The alarm status is reached after the time set on Pr11 (factory setting 90") and can
be reset by pressing and holding the
list on the "Assistance" page of the KLOVER website.
Appliance's conditions after a blackout
Previous state
OFF
CHECK UP
LOAD PELLET
FIRE WAIT
FIRE WAIT / LOAD PELLET
FLAME LIGHT
FLAME LIGHT
WORK (any phase)
WORK (any phase)
BRAZIER CLEANING
BRAZIER CLEANING
FINAL CLEANING
STAND-BY
CS.DLA.IST_EN_Rev. 1.0_11-23
Cause
This occurs when the measured combustion air
flow is below the set threshold. NOT APPLICABLE
TO THIS PRODUCT.
This occurs when the brazier is not correctly
aligned during the cleaning phase (initial or during
shut-down).
button. In case of anomaly, contact the authorised KLOVER Technical Assistance Centre – consult the
O
Blackout duration
Any
Any
Any
Any
Any
Duration < Pr48 (30 sec)
Duration > Pr48 (30 sec)
Duration < Pr48 (30 sec)
Duration > Pr48 (30 sec)
Duration < Pr48 (30 sec)
Duration > Pr48 (30 sec)
Any
Any
Possible solution
Contact the authorised KLOVER Technical
Assistance Centre.
Check that the fire door is properly closed.
Contact the authorised KLOVER Technical
Assistance Centre.
State after power is restored
OFF
CHECK UP
BLACKOUT ALARM
BLACKOUT ALARM
BLACKOUT ALARM
FLAME LIGHT
CLEANER STAND-BY with automatic re-ignition
after machine cooling
WORK (any phase)
CLEANER STAND-BY with automatic re-ignition
after machine cooling
BRAZIER CLEANING
CLEANER STAND-BY with automatic re-ignition
after machine cooling
FINAL CLEANING and after cooling OFF
STAND-BY
EN