Anomalies, causes and possible remedies
Anomaly
Ignition difficulties
Presence of smoke and soot in
the room
The glass dirties very quickly
Condensate build-up
Presence of water in the firebox
and in the ash tray
"SERVICE EXPIRY" message on
the display.
"DEVICE NOT FOUND" message
on the display.
42
Causes
Insufficient combustion air
Non-conforming quality, size and quantity of fuel
Insufficient draught
External air intake not present of with insufficient
cross-sectional size
Fume discharge system clogged or not made
correctly
Loss of smoke from piping
Insufficient draught
Fume discharge system clogged or not made
correctly
Non-conforming quality, size and quantity of fuel
Insufficient draught
Fume discharge system clogged or not made
correctly
Slow combustion and thus excessively low fume
temperature
Fume discharge system and condensate collection
chamber not made correctly
Fume discharge system not made correctly
Hour timer ended
No communication between the appliance and the
remote control
Possible solution
Increase the combustion air intake (see "Adjusting
the combustion air").
Use fuel conforming to the indications given under
the chapter "Fuel".
Open the smoke damper and the primary
combustion air damper.
Clean the brazier (see "Cleaning the brazier").
Clean the ash tray (see "Cleaning the ash tray").
Clean the fume passage (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Check the tightness of the fume pipe.
Check the tightness of the fume pipe.
Check the ash suction machine's filter.
Clean the brazier (see "Cleaning the brazier").
Clean the ash tray (see "Cleaning the ash tray").
Clean the fume passage (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Use fuel conforming to the indications given under
the chapter "Fuel".
Check the cleanliness of the fume exhaust system.
Clean the brazier (see "Cleaning the brazier").
Clean the ash tray (see "Cleaning the ash tray").
Clean the fume passage (see "Cleaning the
combustion chamber").
Contact the authorised KLOVER Technical
Assistance Centre.
Increase the combustion air intake (see "Adjusting
the combustion air").
Use smaller-size and more seasoned wood (see
"Fuel").
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the authorised KLOVER Technical
Assistance Centre.
Contact the Technical Assistance Centre to
perform extraordinary maintenance on the product.
(The number of residual hours for extraordinary
maintenance is indicated in the "STOVE STATUS"
menu in the "SERVICE P" field on the pellet side and
"SERVICE W" field on the wood side)
Check the battery charge.
Check that the remote control is not too far from
the appliance.
Contact the Technical Assistance Service in case of
anomalies on the PCB or remote control.
CS.DLA.IST_EN_Rev. 1.0_11-23