MAINTENANCE
PERIODS OF INACTIVITY
During periods of inactivity, disconnect all the power supplies. Protect the equipment's external steel parts wiping them with a
smooth cloth slightly damped with Vaseline oil.
Leave the door ajar to guarantee a correct air exchange.
For reactivation, before using:
• Carry out thorough cleaning of the equipment and accessories
• Reconnect the equipment to the electrical and water supply
• Have the equipment checked before reusing it
• Restart the equipment at a low temperature for at least 60 minutes without any food inside.
At least once a year, the equipment must be maintained and checked by an authorised service centre. This
ensures that the equipment is always in a perfect working and safe condition.
SERVICE INTERVALS
Service, checks, controls and cleaning
• General routine cleaning of the equipment and the area around it
• Visual check of the integrity of the structure and control panel and the
stability of the equipment
• Check for any deposits of ice in the cell. If they are detected, carry out
manual defrosting, see page
• Check the integrity of the
if it is damaged
Check:
safety
• The status of the
operational, not tampered with
mechanical
• The status of the
intact and not misshapen.
tightening of the screws and
• The correct
must be present and well tightened. If a screw or a bolt is missing, re-
place them with others of the same type and length.
• Legibility and state of the
safety stickers and notices must be perfectly legible and understan-
dable. If not, replace them with others of the same type.
electrical components
• The conditions of the
control panel.
cables
• The integrity of the
the equipment. If they are damaged, replace them with others of the
same type.
connecting
• the state of the
one.
• Check the mechanical parts, the tightness of the screws, the electrical
components, any corrosion, the water circuit (if there is one), the refri-
geration circuit, the functionality of the control panel, stability.
The equipment has been designed and constructed to guarantee a lifetime of about
10 years.
After 10 years of service, the equipment is therefore inspected.
Rev. 0
47
door frame
and
door
seal. Replace the seal
devices. The safety devices must be present,
parts. The mechanical parts must be
bolts. The screws and bolts
safety stickers
and any other notices. The
installed in the electrical
between the electric board and the parts of
cable. If necessary, replace it with a similar
Frequency
Daily
Monthly
Yearly
Every 10 years
54
Who has to do it
User
Technical service
Technical service
Technical service

Publicidad

loading