Descargar Imprimir esta página

KBS PAPRIKA Manual De Uso Y Mantenimiento página 58

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

AFTER-SALE SERVICE
ALARMS
The following table shows the alarms with their solution. The signalling takes place by means of alarm LED
Each alarm is recorded in the Alarms menu
Description
Probe 1 Faulty
Probe 2 Faulty
Probe 3 Faulty
Probe 4 Faulty
Probe 5 Faulty
Minimum temp. alarm
Maximum temp. alarm
High humidity alarm
Blocked compressor (high
condensation)
Condenser overheated
Defrost timeout alarm
Door open alarm
Multifunction input alarm
Digital pressure switch alarm
Thermal protection 1
Thermal protection 2
See chap. "Navigation in the Controls Screen" on page 47).
Cause
• Probe not working
• Probe not connected cor-
rectly
• Incorrect probe type
• Temperature Pb1 < A1 for a
time = A7
• Temperature Pb1 < A4 for a
time = A7
• Humidity Pb5 > SET2-AH1 for
a time = AH7
Condenser temperature
> C7 for a time = C8
Capacitor temperature > C6
Defrost terminated due to
timeout instead of reaching
temperature d2
Digital input enabled
for a time > i2
Digital input activated (iC1 = 2)
for a time = i5
Activation of the pressure
switch alarm caused by the
digital pressure switch
Digital input activated (iC1 = 5)
Digital input activated (iC2 = 4)
Solution
Contact Technical Assistance
Wait for the temperature to drop below the alarm limit
threshold. If the problem persists, contact Technical
Assistance
Wait for the temperature to rise above the alarm limit
threshold. If the problem persists, contact Technical
Assistance
Contact Technical Assistance
Turn the instrument off and on
Contact Technical Assistance
Touch any key
Close the door
Contact Technical Assistance
Contact Technical Assistance
Contact Technical Assistance
Contact Technical Assistance
57
USE AND MAINTENANCE mod. PAPRIKA | Rev. 0
and buzzer.

Publicidad

loading