• Only the special brush supplied should be used for cleaning and should be replaced after 12 months at
the latest
IMPORTANT: Cleaning the Adhesive Surface
1. Spread three drops of the Amoena Soft Cleanser to the dry adhesive surface and then moisten the
special brush with lukewarm water. See diagram 3 Contact page 3
2. Using only the special brush, clean the adhesive surface completely for approx. 2 minutes, applying
pressure and using circular movements until the cleanser foams. See diagram 4 Contact page 3
3. Then rinse with plenty of lukewarm water.
4. Leave to air dry or dry with a hair dryer on a moderate setting. Do not dry the adhesive surface with a
towel.
5. Place the clean and dry protective film on the dried and cleaned adhesive surface and smooth out the
edges.
ADAPT BREAST FORMS
All Adapt Air products are supplied with a pump.
General Instructions for Use Adapt Breast Forms
Amoena Adapt Air are breast forms with an integrated air chamber which can be individually adjusted to
fit the chest wall and the body's natural silhouette. A special pump is required to fill the chamber with air
or drain the air from the chamber. Small quantities of silicone oil, which can form on the cannula of the
pump, do not impair the function and quality of the breast form or pump. Simply wipe away the oil with a
clean cloth.
Adjusting Adapt Air
1. Lay out the breast form and pump ready for use. Breast form and pump are separate.
See diagram 5 page 3.
2. Place the pump (1) under the bra strap on the opposite side so that you have both hands free. Pull the bra
strap off the shoulder of the operated side. Diagram 6 page 3.
3. Connect the pump by removing the grey tag (if present) and inserting the cannula (4) into the opening
(5) of the breast form marked with a white arrow. Open the valve inlet by gently squeezing your thumb
and index finger together. Guide the cannula completely into the valve. See diagram 7 page 4.
4. Put the breast form into the bra cup. Ensure that the hose is connected correctly with the breast form.
See diagram 8 page 4
5. Bring the bra strap back into the correct position. See diagram 9 page 4
6. Now, adjust the breast form to your needs by pressing the pump ball (1). To drain the air, press the black
button on the drain valve (2) and lightly press the breast form against the chest wall.
See diagram 10 page 4
7. Please note: In order to insert or drain air, the cannula must be inserted completely into the valve.
16
4
3
2
1
8. As soon as the correct volume is set, remove the cannula carefully from the valve. The air remains in
the air chamber. See diagram 11 page 4
9. Now the breast form has been adapted to your individual needs. Before wearing the breast form, wipe
the valve with a clean cloth as there may still be a residue of silicone oil from the cannula. Then place
the prosthesis in the pocket of the bra. See diagram 12 page 4.
General Care Instructions for Adapt Air Breast Forms
• When cleaning, ensure that no water enters the valve.
• Due to the valve, we do not recommend you wear Adapt Air when swimming.
• Changes in air pressure can lead to minimal, invisible changes in volume. Adjust the volume with the
pump if necessary.
• Use only the pump supplied with the breast form for any adjustments.
1.
Pump ball
5
2.
Drain valve
3.
Hose
4.
Cannula
5.
Valve opening
ENG
17