Galletti ACQVARIA AQ10Q0B0 Manual De Instalación, Uso Y Mantenimiento página 32

Ventiloconvectores de cassette con motor on/off - 3-10 kw

Publicidad

3.5
EFFETTO GRILLE CONFIGURATOR
3.6
JONIX INSIDE
è disponibile a configuratore la funzione di ionizzazione dell'aria
che avviene attraverso l'attivazione del dispositivo ionizzatore
JONIX, situato all'interno dell'unità.
It is an active air sanitising system, which prevents the formation
of contaminants on internal surfaces and air in transit.
È possibile controllarne il funzionamento grazie ai controllori
EVO, EVO-2-TOUCH e MYCOMFORT LARGE.
For installation instructions referred to the manual FC66006045.
3.7
ACCESSORIES
Electronic microprocessor control panels with display
DIST
MY COMFORT controller spacer for wall mounting
EVO-2-TOUCH 2.8" touch screen user interface for EVO control
EVOBOARD
Circuit board for EVO control
EVODISP
User interface with display for EVO controller
EYNAVEL
Device for Wi-Fi or Bluetooth communication between EVOBOARD and smartphone
LED503
Recessed wall-mounted electronic display controller LED 503
MCBE
MYCOMFORT BASE electronic controller with display
4
DIMENSIONS
In figures 13.3  p. 123 and 13.6  p. 126 shows the dimensions of ACQVARIA and shows the position of water connections.
5
INSTALLATION
A
WARNING:
It is mandatory to install the 3-way (or 2-way)
valve accessory in order to avoid the circulation of cold
water in the exchanger if the unit is not operated for
long periods of time, with the fan off. Install the auxiliary
water drip tray, provided together with the base unit, in
order to prevent valve kits from dripping.
32
ACQVARIA
MCLE
Microprocessor control with display MY COMFORT LARGE
MCME
MYCOMFORT MEDIUM electronic controller with display
MCSUE
Humidity sensor for MY COMFORT (medium e large), EVO
MCSWE
Water sensor for MYCOMFORT and EVO controllers
Electronic microprocessor control panels
TED 2T
Electronic controller for AC fan control and one ON/OFF 230 V valve
TED 4T
Electronic controller for AC fan control and two ON/OFF 230 V valves
TED SWA
Water temperature sensor for TED controls
Power interface and regulating louver controllers
KP
Power interface for connecting in parallel up to 4 fun coil units to the one controller
Valves
PIC-AQ
PRESSURE-INDEPENDENT 2-way valves
2-way valve, ON/OFF or MODULATING actuator, 230 V or 24 V power supply, hydraulic
V2-AQ
kit, for model with 1 or 2 heat exchangers
3-way valve, ON/OFF or MODULATING actuator, 230 V or 24 V power supply, hydraulic
V3-AQ
kit, for model with 1 or 2 heat exchangers
Plenum, air intake modules, air inlet and outlet connectors and cabinets
BAR
Spigot for introduction of mixed renewal air
MOB
Cabinet for cassette
PAR
Plenum for introduction of unmixed renewal air
PMAA
Air outlet plenum
For each unit an (IL) switch should be mounted on the power
supply, with opening contacts at a distance of at least 3 mm
and a suitable protection fuse (F) .
A
WARNING:
before carrying out any operation, check that
the voltage and frequency of the unit correspond exactly
to those of the main power supply.