English
START UP PROCEDURE
The MultiCyclone is an advanced and highly efficient filter system that will provide years of
trouble free service if the following maintenance procedures are maintained.
To start up the filtration system either from new or after cleaning is exactly the same.
1. Ensure that the MultiCyclone is plumbed correctly.
2. Ensure that all valves installed before and after the MultiCyclone are open.
3. Loosen the air release valve on top of the MultiCyclone filter.
4. Prime the swimming pool pump. (Refer to the pump installation and operation manual).
5. Turn on the swimming pool pump and allow the pump to run until all the air has been expelled
from the MultiCyclone. Water will run from the air release valve.
6. Re-tighten the air release valve.
7. The filter is primed and ready for operation.
Note: In some cases this may be required to be done a few times before the unit will remain
primed and be fully operational.
!
Do not stand over the top of the MulitCyclone while adjusting the air release valve to purge
the system of air.
Injury may occur if air release valve becomes loose.