Air Release Valve
MultiCyclone Housing Lid
Clear Poly Carbonate
Sediment Chamber
Water Flow
The accumulation of sediment can be visibly monitored through the MultiCyclone clear sediment
chamber. The Multicyclone sediment chamber is cleaned by simply opening the purge valve.
Only 15 litres (4 gallons) of water is discharged to clean the Multicyclone of sediment.
Note: The MultiCyclone centrifugal section is designed to filter sediment that is heavier than
water; floating debris cannot be filtered out by centrifugal filtration.
Model
Connection Ports
MultiCyclone 12
40mm/50mm (EU)/
1
/
1
50mm/63mm (EU)/
MultiCyclone 16
2" Quick Fit Union
Minimum Flow
40lpm/2.4 m
" Quick Fit Union
2
50lpm/3 m
M/C 12: 40mm/50mm (EU)
/
1
1
" Quick Fit Union.
2
M/C 16: 50mm/63mm (EU)
2" Quick Fit Union.
12/16 Hydrocyclones
Filter Housing Retaining Clamp
Band
Maximum Flow
/hr/
300lpm/18m
3
11gpm
79gpm
/hr/
500lpm/30m
3
13gpm
132gpm
MultiCyclone
25mm/32mm (EU)
1" Purge Valve
M/C 12: 40mm/50mm (EU)
/
1
1
" Quick Fit Union.
2
M/C 16: 50mm/63mm (EU)
2" Quick Fit Union.
Max. Pressure
/hr/
3
350 kPa (50psi)
/hr/
3
350 kPa (50psi)
I pg 03