INSUFFICIENT WATER PRESSURE
In situations where the water flow from the pump is not powerful enough purge the sediment
out of the sediment chamber. Waterco recommends fitting a 2 way valve after the MultiCyclone
on the pool water return line.
The 2 way valve is used to throttle the flow of water out of the MultiCyclone, increasing water
turbulence through the sediment chamber and improving its purging action.
While the pump is operating, open the purge valve, and then partially close the 2 way valve,
throttling the water flow sufficiently to purge the sediment chamber of trapped sediment. Once
the sediment chamber is clean, open the 2 way valve and then close the purge valve.
Installation with 2 way shut off valve Cartridge Filter
!
Do not close the 2 way valve prior to opening the purge valve and do not close the purge
valve while the 2 way valve is closed or partially closed. Both valves should never be closed
or partially closed at the same time.
If the MultiCyclone is installed as a pre-filter to a media filter, water flow to the media filter can
be closed via the media filter's multiport valve.*