Descargar Imprimir esta página

Balluff BMP 02-P A-P Serie Manual De Instrucciones página 46

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

  • MEXICANO, página 117
BMP 02- _ P _ _ _ _ _ A- _ _ _ _ - _ _ -P _ _ /P _ _ -S4/P _ _ -S75
Magnetic Field Positioning System
5
Installation and connection (continued)
5.7
Electrical Connection
BMP 02-...-P_ _-S75
2
4
1
3
M 8-4 (Class A)
Fig. 5-15: Pin assignments for connector (pin side view)
Pin Wire color
Signal
1
Brown
+24 V (operating voltage UB+)
2
White
Analog output: Voltage 0...10 V
3
Blue
GND (operating voltage UB−;
reference potential)
4
Black
OUT1 (switching output S1) or C/Q
(IO-Link)
Tab. 5-1:
Plug connector pin assignment
Connection diagram
BMP 02-AP1...P_ _
BN
BK
WH
BU
BMP 02-AP1...P_ _-S_ _
BN
BK
WH
BU
BMP 02-ZPZ...P_ _-S_ _
1
4
2
3
BMP 02-ZPZ...-P_ _
1
4
2
3
Fig. 5-16: Connection diagram
16
english
BMP 02-...-P_ _-S4
2
1
3
4
M 12-4 (Class A)
S1 / IO-Link
Analog output
S1 / IO-Link
S2
S1 / IO-Link
Analog output
S1 / IO-Link
S2
5.8
Cable routing
Magnetic fields
Ensure that there is sufficient distance between the BMP
and the holding cylinder and strong, external magnetic
fields.
Cable routing
Do not route the cable between the BMP, controller and
power supply near high voltage cables (inductive stray
noise is possible) and ensure EMC-compliant cable laying
or machine installation.
Lay the cable so that the strain on it is relieved (see
chapter 5.10 on page 17).
Bending radius for fixed cable
The bending radius for a fixed cable must be at least three
times the cable diameter.
Cable length
Cable length max. 10 m.
For the analog output longer cables may also be used if
their construction, shielding and routing prevent noise
interference.
5.9
Protect sensor and cable against weld spatter
The sensor surface (touch-sensitive button, status LED)
and the sensor cable can be mechanically protected
against weld spatter using a plastic clip and silicone hose
(see Accessories on page 25).
To reduce sensitivity to interference, external signal
suppression can also be set via IO-Link (see configuration
guide at www.balluff.com on the product page).
Plastic clip
BAM PC-MP-042-02-S/W
Locking lugs
Fig. 5-17:
Components
Silicone hose
BAM PT-XA-009-025-T-00.5
Cable tie

Publicidad