6
Startup
6.1
Starting up the system
Uncontrolled system movement
When starting up, if the position measuring system is part
of a closed loop system whose parameters have not yet
been set, the system may perform uncontrolled
movements. This could result in personal injury and
equipment damage.
► Persons must keep away from the system's
hazardous zones.
► Startup must be performed only by trained technical
personnel.
► Observe the safety instructions of the equipment or
system manufacturer.
Wrong or unexpected signals for constructions with
ferromagnetic content are possible.
► Move the position magnet across the entire
detection range.
1. Check connections for tightness and correct polarity.
Replace damaged connections.
2. Turn on the system.
3. Check measured values and adjustable parameters
and readjust the BMP if necessary. Move the position
magnet across the entire measurement range.
Check for the correct values, especially after
replacing the BMP or after repair by the
manufacturer.
6.2
Operating notes
Regularly check function of the BMP and all associated
components.
Take the BMP out of operation whenever there is a
malfunction.
Secure the system against unauthorized use.
Check fasteners and retighten if needed.