Descargar Imprimir esta página

GiBiDi AS06321 Instrucciones Para La Instalación página 15

Equipo electrónico para la automatización de una cancela de batiente, corredera, puerta basculante o barrera con uno o dos motores de 115 vca

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

F4
5 - ELECTRICAL CONNECTIONS: TERMINAL BOARDS
Terminal
Position
1
2
3
4
5
M1
6
7
8
9
10
M2
11
12
13
14
15
16
17
18
19
20
21
M3
22
23
24
25
26
27
RELAY CLEAN-CONTACT FOR:
28
• Fixed-light flashing light connection taking the power supply from terminals 7 and 8
M4
• Controlling a warning light to signal gate movement. Connect a 24VAC light powered
29
Signal
Description
Motor 1 connection (opening)
Motor 1 connection (common)
Motor 1 connection (closing)
Motor 2 connection (opening)
Motor 2 connection (common)
Motor 2 connection (closing)
COURTESY LIGHT output (LIVE) if DIP1_9 = OFF
Fixed output for FLASHING LIGHT if DIP1_9 = ON
COURTESY LIGHT output (NEUTRAL) if DIP1_9 = OFF
Fixed output for FLASHING LIGHT if DIP1_9 = ON
N
115VAC power supply NEUTRAL
L
115VAC power supply LIVE
Earth wire connection
EARTH
Earth wire connection
EARTH
COM
COMMON for LIMIT SWITCH, PHOTOCELL, STOP, START and PEDESTRIAN inputs
FCCM2
Closing limit switch input - MOTOR 2 (N.C.)
Opening limit switch input - MOTOR 2 (N.C.)
FCAM2
Closing limit switch input - MOTOR 1 (N.C.)
FCCM1
FCAM1
Opening limit switch input - MOTOR 1 (N.C.)
PHOTO
PHOTOCELL input (N.C.)
START input (N.O.)
START
24VAC output for PHOTOCELL, ACCESSORIES power supply (max 8W)
24Vac
0Vac
0VAC output for PHOTOCELL, ACCESSORIES and ELECTRIC LOCK power supply
EL1
12VAC output for ELECTRIC LOCK (max 15W)
STOP input if DIP2_1 in OFF - EDGE input if DIP2_1 in ON.
STOP
If not used, make a bridge with terminal 25 and open jumper SW15.
PEDESTRIAN start input (N.O.) - ACTS ON MOTOR 1.
PED
The pedestrian operation is made using automatic logic and cannot be modified.
COM
COMMON for LIMIT SWITCH, PHOTOCELL, STOP, START and PEDESTRIAN inputs
ANTENNA BRAID input
COM
ANTENNA CORE input
(the relay flashes fast during closing and slow during opening).
by terminals 20-21 (max 3W). The light flashes fast during closing, slow during
opening, it is on during pause and it is off during sleep time.
15
UK

Publicidad

loading

Este manual también es adecuado para:

F4