Special Features - Solter Aerotig 4320 DC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

SPECIAL FEATURES

You can access special features using the FNP menu option.
The modification of advanced parameters can significantly alter correct operation of the machine.
Change these settings at your own risk. If you notice irregular operation of the machine, reset the pa-
rameters to their default values, or select the "dEF" menu option to return the setting of all operating
Default
Function
value
P.01
ON
P.02
OFF
P.03
OFF
P.04
OFF
P.05
-
P.06
-
P.07
OFF
P.08
ON
P.09
Normal
P.10
-
P.11
Normal
P.12
Normal
P.13
Normal
P.14
-
P.15
Normal
P.16
Normal
P.17
4
P.18
50
P.19
-
SOLTER
SOLDADURA S.L.
parameters and settings to their respective default values.
Live View mode
Enables viewing of the status of the welding process on the configuration chart of the
control panel during the execution of the weld.
Only compatible with Live View enabled.
OFF - shows the reference welding amperage.
ON - shows the actual amperage reading present in the welding arc.
ON - Enables remote MMA setting mode. See P.23 and P.24.
OFF - Local control
ON - Enables amperage reduction system by increasing the arc height for MMA wel-
ding processes.
OFF - Disabled
Not available in this model.
Not available in this model.
ON - Enables pilot arc ignition in TIG mode.
OFF - Normal ignition.
ON - Enables display of average welding voltage at the end of the weld bead.
OFF - Disabled.
For two button TIG torches.
It allows you to define which one is the main button and which one is the secondary.
Not available in this model.
Allows you to select the type of main button. Normal for open (NO) or inverted for
closed (NC).
Allows you to select the type of secondary button. Normal for open (NO) or inverted
for closed (NC).
Allows you to select the type of pedal accessory. Normal for open (NO) or inverted
for closed (NC).
Not available in this model.
Allows you to invert the minimum and maximum position of the remote potentiometer
of the torch.
Allows you to invert the minimum and maximum position of the remote potentiometer
of the pedal.
Torch length, in meters. Allows you to compensate the voltage reading.
Cable section in torch, in mm
Not available in this model.
ATTENTION
Description
. Allows you to compensate the voltage reading.
2
AEROTIG DC
37

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aerotig 4330

Tabla de contenido