Maintenance Instructions; Connection With Aerocool Cooling Unit - Solter Aerotig 4320 DC Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

MAINTENANCE INSTRUCTIONS

Regular monitoring of the machine is recommended. Before performing any maintenance, disconnect the machine
from the mains. Reduce the recommended maintenance intervals in situations of intensive use.
Interval
Weekly
Quarterly
Annual
The handling of internal parts of the machine should be performed only by qualified personnel.
There is a risk of electric shock on contact with live parts. You should NOT operate without the covers pro-
perly placed. Before accessing the interior of the machine, unplug it from the mains and wait at least 5 mi-

CONNECTION wITH AEROCOOL COOLING UNIT

The planned operation of the cooling unit is fully automatic. Check cooling unit operation mode. The advanced set-
ting parameter P.36 must be normal / automatic mode (nor).
You must select disabled, "dis", in P.36 advanced setting parameter.
Connect the cooling unit to the remote connector at the base of the power unit. It may be necessary to remove the
protective cover.
Please, make sure that once the cooling unit and power unit are interconnected, the connection is well secured to
avoid false contacts of the interconnecting cable.
During the first use, you may need to check the priming of the coolant in the circuit. The machine will try to do it auto-
matically. Alarm message 10 may appear during the process.
For more information on the operating modes of the cooling unit, please, see the description of advanced setting pa-
rameter P.36 in this manual and/or the Aerocool cooling unit manual.
SOLTER
SOLDADURA S.L.
Check the condition of wiring and external accessories.
Blow out the feed guide of the torch with compressed air and replace worn components.
Clean and tighten the electrical connections of the welding circuit
Clean the drive unit with compressed air.
Remove all rollers from the drive unit, clean to remove dust and dirt and lubricate slightly.
Carry out a complete inspection as specified by the standard EN-60974. See your dealer.
nutes before carrying out any maintenance.
If your equipment configuration DOES NOT have a cooling unit.
Action
ATTENTION
ATTENTION
AEROTIG DC
39

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Aerotig 4330

Tabla de contenido