The following table lists the possible alarms that can appear during operation of the machine. These alarms DO NOT
imply a machine malfunction. They are displayed in the event that the operating cycle is exceeded or due to a lack of
proper maintenance. Alarms in the 10-15 range must be validated manually by pressing the main control button,
once their causes have been checked. Do not validate the alarm without checking its cause and carry out the appro-
priate maintenance. If the machine is kept operating for too long with displayed alarms, this could cause a failure.
This failure will not be covered by the machine guarantee due to inadequate maintenance.
ALARM code
A.01
A.02
A.03
A.04
SOLTER
SOLDADURA S.L.
Fault in program memory data integrity.
Restart the machine. During the startup process, the machine will attempt to recover the
defective memory sectors
Fault in user interface control system.
Calibration error in the temperature reading of the main inverter stage.
Calibration error in the temperature reading of the output power stage.
Calibration error in the temperature reading of the input stage.
Calibration error in the auxiliary temperature reading.
User interface version is not supported.
Data program version is not supported.
Corrupt operating parameters.
Synchronization between main control unit and user interface is pending.
Detection of different user interface from the original.
User interface is not supported.
Data memory is not initialised.
Verification of user interface compatibility and main control is incorrect.
Error in factory calibration.
Wrong serial number.
Failure in the software updating process of the main control unit.
Excess of temperature at the main inverter stage. Wait until the machine regains a safe
temperature at this stage. Ensure that the vents are not clogged.
Excess of temperature at the output power stage. Wait until the machine regains a safe
temperature at this stage. Ensure that the vents are not clogged.
Excess of temperature at the output power stage. Wait until the machine regains a safe
temperature at this stage. Ensure that the vents are not clogged.
Excess of temperature at the auxiliary stage. Wait until the machine regains a safe tem-
perature at this stage. Ensure that the vents are not clogged.
Description
AEROTIG DC
41