Descargar Imprimir esta página

Sew Eurodrive X e Serie Instrucciones De Montaje Y Funcionamento página 247

Reductores industriales, accionamiento de elevador de cangilones, clases de par de 7.2-285 knm
Ocultar thumbs Ver también para X e Serie:

Publicidad

5
Example: speed monitoring in a wind power station
1: sensor at the rotor or generator shaft
2: wind power station
3: switching outputs
4: analogue output
5: signals depending on the selected switching functions
6: recording or display
WARNING
The device is not approved for safety-related tasks in the field of operator
protection�
Using an electrical connection of the outputs from two or more units to achieve
a redundant circuit, they can also be used for safety-related tasks� All applicable
technical standards must be followed�
Instrucciones de montaje y funcionamiento – Accionamiento de elevador de cangilones – Serie X..e
In 1
6
MONITOR
FR-1
Out 1 Out 2 Out 3
4
3
Documentación del proveedor
1
2
11
UK
7
247