As soon as the pushbutton is released, the active decade flashes� It is set by
pressing [▲] or [▼] several times. The preceding decade then flashes and can be
set�
8.2.4 Factory Reset
The factory default values can be restored by pressing [▲] and [▼] simultaneously
during power on� All previously entered parameter values are lost�
8.2.5 KEY function (locking)
The unit can be locked to prevent incorrect entries�
After locking, only the actual value indication can be switched with the [▲] and [▼]
buttons� Parameter range and PRG mode can no longer be selected�
Locking
► Press [▲] and [▼] simultaneously
and hold them pressed�
> The KEY indicator flashes�
► Release the pushbuttons when
the KEY indicator is continuously
indicated�
Instrucciones de montaje y funcionamiento – Accionamiento de elevador de cangilones – Serie X..e
Documentación del proveedor
Unlocking
► Press [▲] and [▼] simultaneously
and hold them pressed�
> The KEY indicator flashes�
► Release the pushbuttons when the
KEY indicator is no longer indicated�
11
UK
21
261