Service & maintenance information
Service and maintenance of a medical device is wholly the responsibility of the owner of that device.
Failure to service and maintain a device in accordance with the instructions may invalidate the device's
warranty. Furthermore, failure to service and maintain a device may compromise the clinical condition or
safety of users and/or their caregivers. Do not perform service and maintenance while the user is in the
product. Contact the local dealer for assistance, if needed, in setting up, using or how to perform service
and maintenance of the device.
Lifetime
The lifetime of this product in normal use is 8
years if all maintenance and servicing is carried
out in accordance with the manufacturer's
instructions and demonstrably recorded.
Reuse
This product and its accessories/components are
suitable for reuse.
Refurbishment for reuse
Before reuse or changing the user, follow the
service checklist, maintenance and washing
instructions and carry out regular inspections.
Service interval
The frequency of inspection may be altered
depending upon use and wear. It is recommended
that the product is inspected yearly, every time
the product is re-issued for use and after a
long-term storage (more than 4 months). The
inspection should be carried out by a person who
understands the use of the product.
Service checklist:
Check and adjust the following as per their
intended use:
• Cushioning.
• The push-brace can be angle adjusted.
• If equipped with airfilled tyres, check the air
pressure.
• Seat plane adjustment. The seat plane
is adjustable and stays in position after
adjustment.
• Wheels are moving freely and that all wheel
locks/brakes are easily activated.
• Nuts and bolts on the product are tightened.
• Fittings and buckles for signs of worn out
parts.
• Product for cracks or signs for worn-out parts.
• Seat docking is clean and functional.
• Product can be folded for storage or
transportation.
• Seat back is adjustable and can be locked in
position.
• All labels on the product are intact.
Repair or replace any damaged or worn out parts.
Maintenance
Before every use it is recommended to:
Wipe off any residue and dirt from the product,
using a cloth with warm water and a mild
detergent/soap without chlorine and let it dry
before use.
EN
Carry out a visual inspection, for any damaged or
worn-out parts.
Washing
Main product
This product can be washed at 60° using a mild
detergent for 10 minutes in a washing machine
designed for medical devices. Use the machine's
drying function to dry the product. Unmount all
accessories and wash them separately.
Fabric and covers
The cover can be washed at max. 60°C using a
mild detergent in a washing machine.
Foam
It is not recommended to wash the foam parts.
Handwash
This product and its accessories can also be
washed by hand. Use warm water and a mild
detergent/ soap without chlorine and let all parts
dry before use.
Disinfection
The product can be disinfected with a 70%
disinfectant IPA solution. It is recommended to
wipe off any residue and dirt from the product,
using a cloth with warm water and a mild
detergent/soap without chlorine and let it dry
before disinfection.
Materials
• Aluminium
• Plastic
• Rubber
• Polyurethane
• Neoprene
• Ipanema
• Steel
• Zinc alloy.
Surface treatment
The following surface treatment processes were
used to protect against corrosion:
• Lacquered surfaces = Polyester powder
coating or ED-coating
• Non-lacquered aluminium parts = Anodized
coating
• Non-lacquered steel surfaces = Galvanized.