Polaris
FREEDOM
PLUS Cordless Robotic Cleaner | Owner's Manual
®
™
7.3
Cleaner Error Codes
On/
Blinking Red
Off
red
Remains orange after
12 hours on the charger
Error
Display in the
#
iAquaLink
Communication
10
error
14
Motor Block
Error
2 & 3
Traction motor
right/left
Drive motor
5 & 6
consumption
right/left
7
Cleaner Floating
Cleaner out of
the water
8
Pump motor
1 & 4
red
31
Antenna Error
12
Firmware Update
Error
®
App
• The cleaner board is under power but
does not respond.
• Contact your service center for a
diagnostic review or contact Technical
Support at 1.800.822.7933.
• Check that debris is not preventing the
brushes or tracks from moving freely.
• Rotate each wheel by a quarter of a
turn in the same direction until it rotates
smoothly. Repeat turning wheels in
the opposite direction until rotation is
smooth.
• Contact your service center for a
diagnostic review or contact Technical
Support at 1.800.822.7933.
• Thoroughly clean the filter canister.
• Restart the cycle, then submerge cleaner
in the water and shake to release air
bubbles.
• Contact your service center for a
diagnostic review or contact Technical
Support at 1.800.822.7933.
• Turn off the cleaner using the slider by
sliding to the left and hold for 20 seconds
while off of the charging station. No LEDs
will be illuminated.
• Check for small debris or hair in the fan
impeller.
• Thoroughly clean the filter canister.
• Contact your service center for a
diagnostic review or contact Technical
Support at 1.800.822.7933.
• The antenna is damaged and the cleaner
cannot be controlled with the remote.
• Contact your service center for a
diagnostic review or contact Technical
Support at 1.800.822.7933.
• Close the iAquaLink
• Check that the cleaner is connected to
the Wi-Fi network (the LED is solid blue).
• If the indicator is not steady, open the
app, select the cleaner and
iAquaLink
®
click on "Update".
Solutions
®
app.
Page 19