• NEVER store a spare L.P. gas supply cylinder under the grill
body or inside the grill enclosure or in the vicinity of any
heat producing appliance.
Failure to follow this information exactly could result in an
explosion and/or fire causing death or serious injury.
Tighten by hand only. DO NOT use tools.
1.
Before attaching propane
cylinder make sure all
control knobs are closed.
(Fig. 20)
2.
Remove plastic cap from
top of propane cylinder
and screw cylinder into
regulator hand tight.
(Fig. 21)
Note: A slight upward
pressure may need to be
applied to start threads.
WARNING
DO NOT operate the grill with side tables in storage position.
Damage will occur and void the warranty.
1. To extend side tables, grasp hold of side tables on
bottom of grill and slide out until fully extended. (Fig. 22)
Burner and Orifice
1.
Proper location of the burner with respect to the orifice is
important. To verify the proper installation of the Venturi
tube. The venturi tube must be located over the orifice
fitting. See Fig. 23 (control panel not shown).
DANGER
CAUTION
Side
table
Orifice fitting
2.
Check and clean the burner/venturi tubes for insects and
insect nests. A clogged tube can lead to a fire beneath the
appliance. Refer to the section titled
"Cleaning the Venturi").
Leak Testing - Disposable LP Gas Cylinders
To Prevent Fire or Explosion Hazard:
Fig. 20
• NO SMOKING. DO NOT use or permit sources of ignition in
the area while doing a leak test.
• Perform leak tests outdoors only.
• NEVER perform a leak test with fire or flame.
How to Check for Leaks
1.
Make a soapy solution of equal parts mild liquid
dishwashing detergent and water.
Fig. 21
2.
Turn off the burner control knobs.
3.
Apply a soap solution to the connections indicated with
the arrow. (Fig. 24) If bubbles appear at these areas, a leak is
indicated.
No Smoking
No Flame
Fig. 22
English - 7
Venturi tube
Burner
DANGER
Fig. 23
Fig. 24