Operating time limitation
The Fulgor Milano induction appliances all feature safety time-
outs (Operating Time Limitation or OTL) on the induction
cooking zones. The following table shows the various OTL for
each inductor before timing out based on what power level is
chosen. (Also applies to bridged zones or induction griddle
depending on model). Thus, longer, overnight simmering is
possible on settings 1, 2, or 3.
Error codes
Error codes are displayed by the 7-segment display with "E" or "ER" plus the error number.
Error message
/ H
ER20
ER21
ER22
ER31
ER36
ER40
ER47
EA
U400
E2
E4
E5, E8, EA
Description
Permanent use of keys;
TC switches off after a certain period of time
Internal error in touch control
Over temperature
Internal error in touch control
Variant detection error
Internal error in touch control
Power supply voltage too low on secondary side Check connected components for overload
LIN communication error
Communication error
Overvoltage due to wrong connection
Over temperature of power board
Internal error on power board
Relay error on power board
OTL – Operating time limitation
Level
Specs [h]
Low
2
1
18
2
18
3
18
4
4.3
5
3.5
6
2.3
7
2.3
8
1.8
9
1.5
Remedy
Water or cooking utensils on the glass; Clean
the surface
Replace touch control
Let cooktop cool down
Check heat partitioning for TC
Replace touch control
Download correct configuration
Replace touch control
Replace touch control
Check LIN cabling
Check cabling between touch control and power
board
Replace touch control
Replace power board
Turn off power supply voltage and connect
cooktop properly
Allow cooking zone to cool down
Replace power board
Replace power board
EN
Timeout U&C [h:m]
2:00
18:00
18:00
18:00
4:15
3:30
2:15
2:15
1:45
1:30
13