Fagor ADVANCE Serie Manual De Uso Y Mantenimiento página 38

Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

ENGLISH
DESCRIPTION
The VAC is observed to have been running for 1 or more minutes and the minimum
level has not been reached.
CONSEQUENCE
It is only possible to operate in Convection mode
E10: CV Fault
DESCRIPTION
If TG<93ºC, when CV is active, in 3 minutes, TG does not rise 3 or more degrees.
CONSEQUENCE
I
t is only possible to operate in Convection mode
E11: CC Fault
DESCRIPTION
The CC operates and in 12 minutes, the TC does not rise 3 or more degrees.
CONSEQUENCE
The oven is completely disabled
E12: Temp. High
DESCRIPTION
The controller NTC reaches 60ºC, but does not exceed 70ºC
CONSEQUENCE
The oven operates normally and the bell is not heard. This message is displayed for 3
seconds every 30 seconds.
E13: VCC fault
(Only GAS ovens)
DESCRIPTION
VCC does not respond to the gas control and is at maximum speed.
CONSEQUENCE
The oven is completely disabled
E14: VCC fault
(Only GAS ovens)
Description: VCC does not respond to gas control and has stopped.
CONSEQUENCE
The oven is completely disabled
E15: VCC fault
(Only GAS ovens)
DESCRIPTION
VCC does not respond to the gas control and the speed is not stable.
CONSEQUENCE
The oven is completely disabled
E16: VCV fault
(Only GAS ovens)