11.4
DAMAGED SMOKE EXTRACTION FAN ALARM
It goes off when the smoke extraction fan breaks down. If this
happens, the stove does stop and the display will show up the
following alarm (see drawing D75). Right after, the turn-off stage will
be immediately activated.
To deactivate the alarm press button 4 and the stove will come to the
normal state after doing the final cleaning.
11.5
IGNITION FAILURE ALARM
In case of ignition failure (after 20 minutes at least) the display will
show up an alarm as follows (see drawing D76).
To deactivate the alarm press button 4 and the stove will come to
the normal state after doing the final cleaning.
11.6
SWITCHING-OFF FAILURE DURING WORKING PHASE
If the flame extinguishes during the working stage and the smoke
temperature goes lower than the minimum working threshold,
the alarm does go off and the turn-off stage will be immediately
activated (see drawing 77).
To deactivate the alarm press button 4 and the thermo-stove will
come to the normal state after doing the final cleaning.
11.7
THERMAL ALARM
If during the working phase the thermal security alarm shows up
(see drawing D78), the turn-off stage will be immediately activated.
This alarm means an overheating of the internal part of the tank; this
device blocks the operation of the machine. The restart needs to be
done manually by an authorised technician.
The restoration of the 90ºC safety device is not included in the
warranty unless the technical assistance centre demonstrates a
faulty component.
11.8
COMBUSTION CHAMBER PRESSURE ALARM
It happens when there is a pressure change in the combustion
chamber (door open, dirt registers, air returns...). The electronic
pressostat blocks the working of the stove and shows the alarm.
After that the turn-off stage will be immediately activated (see
drawing D79).
11.9
LACK OF PRIMARY AIR INTAKE FLOW ALARM
Your stove has a flow sensor placed inside the primary air suction
pipe. It detects the proper circulation of combustion air and the
smoke exhaust. In case of insufficient air inlet (due to incorrect
smoke outlet or improper air intake), the sensor sends a "block"
signal. After that the turn-off stage will be immediately activated (see
drawing D80).
11.10
AUGER FAILURE ALARM
The control of the fuel amount to the stove is automatically made
through the electronic programming. It goes off in the event of the
endless breakdown. If this happens, the stove stops and the display
will show up the following alarm. Right after, the turn-off stage will be
immediately activated (see drawing D81).
If this alarm appears you must contact the technical support service.
11.11
FLOW SENSOR ANOMALY ALARM
In case of anomaly of the flow sensor, placed on the primary air
aspiration tube, a blockage signal is send to the stove and right after
the turn-off stage will be immediately activated. (See drawing D82).
If this alarm appears you must contact the technical support service.
INSTALLATION, OPERATING AND SERVICING INSTRUCTIONS
ALARM 4
ASPIRATION
FAILURE
ALARM 5
IGNITION
FAILURE
ALARM 6
NO PELLET
ALARM 7
SECURITY
THERMAL
ALARM 8
PRESSURE
FAILURE
ALARM 9
FLOW
ALARM
ALARM b
AUGER
ERROR
ALARM
FLOWMETER
FAILURE