Index (dec.) Parameters
0x0010 (16)
Vendor Name
0x0011 (17)
Vendor Text
0x0012 (18)
Product Name StringT (max. 48 bytes) Read
0x0013 (19)
Product ID
0x0014 (20)
Product Text
0x0015 (21)
Serial Number
0x0016 (22)
Hardware
Revision
0x0017 (23)
Firmware
Revision
0x0018 (24)
Application
Specific Tag
Application Specific Tag
The Application Specific Tag makes it possible to assign
the IO-Link device an arbitrary, 32-byte string.
This can only be used for application-specific identification
and applied in the parameter manager. The entire object is
accessed via subindex 0.
6.4

System commands

Different commands have been implemented in the BML
which can be reached via the parameter System
Command on Index 2, Subindex 0. If a system command
is transferred to the BML, the command triggers the
desired action if permitted in the current application state.
Command
Name
0x01 (1)
ParamUploadStart
0x02 (2)
ParamUploadEnd
0x03 (3)
ParamDownloadStart
0x04 (4)
ParamDownloadEnd
0x05 (5)
ParamDownloadStore
0x06 (6)
ParamBreak
0x82 (130)
Restore Factory Settings
0xE0 (224)
Teach In Zero Point
0xE1 (225)
Reset Offset
0xE3 (227)
Teach In Minimal Negative
Position
Tab. 6-1:
System commands Index 2, Subindex 0
www.balluff.com
Data format (length)
Access Contents
StringT (7 bytes)
Read
StringT (15 bytes)
Read
StringT (16 bytes)
Read
StringT (max 64 bytes) Read
StringT (16 bytes)
Read
StringT (2 bytes)
Read
StringT (8 bytes)
Read
StringT (max. 32 bytes) Read/
Write
Description
Starts parameter upload.
Ends parameter upload.
Starts parameter download.
Ends parameter download.
Finishes parameter setting and starts data storage.
Cancels parameter setting.
Resets all parameters to their factory settings.
Learns the current position as the zero point
(see Section 6.5.1 on page 20).
Sets the offset to 0 (see Section 6.5.1 on page 20).
Learns the current position as the negative limit
(see Section 6.5.1 on page 21).
BALLUFF
www.balluff.com
e.g.: BML SL1-ALZ0-U1ZZ-ZU1L-S4
e.g. B.: BMLL1IOL1011
Linear absolute magnetic encoder
e.g.: DE160600005422
e.g.: 01
e.g.: 1.04.000
Date retention
X
Compatibility
mode
X
X
X
X
X
X
X
X
english