Process Data Structure (Pd Input Descriptor); Diagnostic Data; Error Messages - Balluff BML SL1-ALZ Serie Manual De Instrucciones

Ocultar thumbs Ver también para BML SL1-ALZ Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • MX

Idiomas disponibles

BML SL1-ALZ _ -U_ ZZ- _ U1L - _ _ _ _
Absolute magnetic encoder system
6
IO-Link Smart Sensor Profile (BML SL1-ALZ0-U1ZZ-...) (continued)
6.5.5

Process data structure (PD Input Descriptor)

This parameter describes the composition of the process
data variables used.
BML SL1-... processes the process data variable as
follows:
Subindex
Values
0x03
0x01
0x20
0x00
Tab. 6-6:
Process data structure
6.5.6

Diagnostic data

Index
Subindex
Parameters
0x0028 (40)
0
Process Data Input
Tab. 6-7:
Diagnostics parameters
6.6

Error messages

The following error messages are stored for failed
parameterization:
Error code
Error message
0x8011
Index not available
0x8012
Subindex not available
0x8020
Service temporarily not available
0x8030
Value out of range
0x8033
Parameter length overrun
0x8034
Parameter length underrun
0x8036
Function temporarily unavailable
Tab. 6-8:
IO-Link specification error messages
www.balluff.com
Description
Signed Integer
32-bit length
0-bit offset
Size
Access
4 bytes
Read Only
Values
This parameter contains the current position value
or the last position value before an error occurred.