5.1) SELECTABLE FUNCTIONS:
The FUNCTIONS dip-switch lets you select the various possible functioning modes and to enable the functions you want.
1 2 3 4 5 6 7 8 9 10
Switches 1-2:
Switch 3
Switch 4
Switch 5
Switch 6
Switch 7
Switch 8
Switch 9
Switch 10
For any switch that is OFF the corresponding function will not be activated.
Switches 1-2:
When in the "Hold to run" functioning mode, the gate/door will only move for as long as the key is pressed down.
In the "Semiautomatic" mode one command pulse will cause the gate/door to carry out a movement in one direction only, until it
reaches the set distance. In the "Automatic" functioning mode, an opening is followed by a pause time and then a closing
manoeuvre.
The "Always Closes" function will, subsequent to a temporary power cut when the gate/door is open, cause a closing manoeuvre
to start automatically preceded by 5 seconds of preflashing.
Switch 3:
In the Condominium functioning mode, once an opening manoeuvre has started, for instance with a Step-by-Step pulse, this
movement cannot be interrupted by any other command pulses until the gate/door has finished opening. During a closing
manoeuvre, a new command pulse will stop the gate/door and reverse direction, opening it..
Switch 4:
The Step-by-Step cycle is normally: OPEN-STOP-CLOSE-STOP; in this functioning mode the Step-by-Step cycle becomes:
OPEN-CLOSE-OPEN.
Switch 5:
With a command pulse, flashing is activated first and after 5 seconds (2 seconds if on manual) movement starts.
Switch 6:
The flashing light is normally activated only during the opening and closing manoeuvres; this function means that the flashing
light remains active also during the Pause Time to signal the "closing soon" condition.
Switch 7:
With this function the gate/door can be kept open only for the length of time needed for transit; it will always close automatically
5 seconds after the last object has passed by the "Photocell", irrespective of the programmed Pause Time.
Switch 8:
As a rule the safety "Photocell" only triggers in the closing cycle; if switch n° 8 is turned "ON", triggering will cause the gate/door
to stop even in the opening phase; if on Semiautomatic or Automatic, movement will start again, in opening, immediately after
the last object has passed by the Photocell
Switch 9:
28
Off Off = "Hold to Run Control" Functioning
On Off = "Semiautomatic" Functioning
Off On = "Automatic" functioning (Automatic Closing)
On On = "Automatic+Always Closes" functioning
On
= Condominium functioning
On
= Cancels STOP in the Step-by-Step cycle
On
= Preflashing
On
= Flashing also in Pause
On
= Recloses straight after Photocell (only if on Automatic)
On
= Safety (Photocell) also in opening
On
= Safety (Photocell+Photocell2) also at the beginning of each movement
On
= Automatic realignment, if required, when power comes back
Off Off = "Hold to Run Control" Functioning
On Off = "Semiautomatic" Functioning
Off On = "Automatic" functioning (Automatic Closing)
On On = "Automatic+Always Closes" functioning
On
= Condominium function
On
= Cancels STOP in the Step-by-Step cycle
On
= Preflashing
On
= Flashing also in Pause
On
= Recloses straight after Photocell (only if on Automatic: Sw 2 = ON)
On
= Safety (Photocell) also in opening
On
= Safety (Photocell+Photocell2) also at the beginning of each movement