6.4 PNEUMATIC HOOK-UP
For correct pneumatic hook-up, proceed as follows:
1) Lower the pedal (5, Fig. L) all the way down to avoid sudden opening of
the clamps.
2) Connect the machine to a compressed air supply (with recommended oper-
ating pressure of 8 - 10 bar) by means of the coupling (23, Fig. G1) supplied
as standard, using a 7 – 8 mm (internal Ø) rubber hose for compressed air.
WARNING!
The compressed air pressure must not exceed 16 Bar.
3) If your tyre changer is not provided with its own inflation device (GP version),
a connection (24, Fig. G2) can be fitted on the back to fit an inflation gun.
WARNING!
Use the union (24, Fig. G2) only for the outlet of air
(to connect inflating device).
Do not connect the compressed air network to this
union: you could break the pneumatic equipment and
the safety devices.
Before making any electric hook up, check to be certain that the mains voltage corresponds to what is stamped on the voltage tag
(attached on the feeding cable of the tyre changer).
It is absolutely essential that the system is equipped with a good grounding circuit.
The machine must be connected to a power supply line circuit breaker set for 30mA.
Note the required power draw as highlighted on the tag-plate fixed to the back of the tyre changer. Check to make sure the shop electric
wiring circuit is dimensioned sufficiently to carry this.
WARNING!
Work on the electric system, even if minor, must be done exclusively by professionally qualified personnel.
Manufacturer shall not be liable for any injury to persons or damage to things caused by failure to comply with
these regulations and can cancel warranty coverage.
1- Prepare the following tools: N. 1 - Hex spanner 13; N. 1 - Electric drill; N. 1 - Concrete drill bit diam. 13 long; N. 4 - Metal expansion screw
anchors 13x50; N. 4 - M 8 x 50 anchor screws.
2- Drill four holes in the floor corresponding to the holes pre-drilled in the base. Holes should be 80 mm deep. Use the long, 13 mm concrete
drill bit.
3- Insert the expansion plugs and tighten with the 13 mm spanner.
S 45 Basic
6.5 ELECTRIC HOOK UP
6.6 FIXING TO THE GROUND
28