K Iv steaM Plus coNtrol
Warning
Type of Malfunction / Cause
A13
-
Filling failure at the start of
steaming in the first 3
minutes, i.e. lower and
upper water levels not
reached (e.g. during initial
start-up)
-
Solenoid valve error
-
Level sensor error
(Symptom: Water emerges
from the drain pipe during
steam operation)
-
Steam module error
A14
-
Filling at the start of
steaming in the first 3
minutes insufficient, i.e.
lower water level reached,
but not upper water level
A16
-
Maximum cabin
temperature of 55°C
exceeded
A17
-
Drain process of steam
generator defective
A18
-
Measured values from
cabin temperature sensor
out of tolerance
A19
-
Steam generator is filled up
or is filled particular when
starting
As soon as a warning is displayed, the steam function can no longer be used!
Warnings can be not deleted; press the light push-button to ignore a warning. If the functional state does not change, the
warning is displayed again when the respective function is selected again.
After pressing the light push-buttom at warning A19, an automatic drain process of steam generator will be starting.
Error messages can be eliminated without loss of data with a mains reset (switching the FI switch off and on again after 10
seconds).
Possible Cause
-
Ball valve before steam
generator closed
-
Filter in connection bracket
of steam generator clogged
-
Insufficient on-site water
supply
-
Solenoid valve defective or
disconnected
-
Level sensor defective or
disconnected
-
Steam module defective or
no voltage supply
-
Ball valve before steam
generator closed
-
Filter in connection bracket
of steam generator clogged
-
Insufficient on-site water
supply
-
Solenoid valve defective or
disconnected
-
Safety cut-out when
maximum allowed cabin
temperature exceeded
-
Generator calcified, i.e. drain
outlet and / or pipe clogged
-
Cabin temperature sensor
defective or disconnected
-
Solenoid valve defective
(untight)
Possible Clearance
-
Open ball valve
-
Clean filter in connection
bracket
-
Ensure sufficient water
supply
-
Replace solenoid valve
membrane or connect
cable (cable on steam
module with "Fill" marking)
-
Replace level sensor or
connect cable (cable on
steam module with "Level"
marking)
-
Replace steam module or
connect cable (cable on
steam module with "Mains
230V" marking)
-
Open ball valve
-
Clean filter in connection
bracket
-
Ensure sufficient water
supply
-
Replace solenoid valve
membrane or connect
cable (cable on steam
module with "Fill" marking)
-
Allow cabin to cool down
-
Remove generator and
clean generator including
drain pipe
-
Replace or connect cabin
temperature sensor
-
Clean solenoid valve
membrane or replace it
83