Operating instructions SATAjet 1000 K RP/HVLP, SATAjet 1000 H RP
• The following applications and operations lead to the loss
of the explosion protection and are, therefore, prohibited:
• Use of the spray gun in explosive areas belonging to ex-zone 0!
• Do not use solvents and cleaning agents based on halogenised
hydrocarbons! Chemical reaction which may occur when using these
substances may be explosive!
7.
Use
• Use only solvent-resistant, antistatic, undamaged and technically
flawless compressed air hoses with a permanent pressure resistance
of minimum 10 bar / 145 psi, e.g. Art. No. 53090!
The following requirements must be fulfilled:
• Use of a compressed air connection G 1/4 a or of a fitting SATA con-
nection nipple.
• Ensure minimum compressed air volume (air consumption) and pres-
sure (recommended spray gun inlet pressure) according to chapter 2.
• Clean compressed air, i.e. with SATA filter 100, Art. No. 148247,
outside the spray booth or SATA filter 484, Art. No. 92320 in-
side the spray booth
• Use an air hose with minimum 9 mm inner diameter (see warnings),
e.g. Art. No. 53090.
1. Check if all screws [2-1], [2-2], [2-3], [2-4] and [2-5] have been
tightened firmly. Tighten fluid tip [2-1] firmly by hand (14 Nm) accord-
ing to [7-4]. Check if locking screw [2-5] has been firmly tightened
according to [10-1]. Tighten, if necessary.
2. Adjust air cap: vertical spray fan [2-6], horizontal spray fan [2-7].
3. With SATAjet 1000 K: Connect the material hose of tank or pump,
resp. to spray gun material connection.
With SATAjet 1000 H RP: Mount the suction cup [2-8] with strainer
Danger! Risk of explosion!
Danger! Risk of explosion!
Information!
US
445